Pump stundart size | Delivery
m3/h |
Head
m |
Rolational speed
с-1 (rot/min) |
Permissible cavitation reserve m, no more | Power of el. Drive
kWt |
|
m3/h | l/s | |||||
АХ315-50 | 315 | 87,5 | 50 | 24 (1450) | 6 | 63 |
АХ315-50а | 285 | 79 | 40 | 45 | ||
АХ315-50b | 260 | 72 | 32 | 33 |
PUMPS АХ 315/50
The electric pump unit of the AH 315/50 type is designed for pumping chemically active and neutral liquids with a density, max, 1850 kg/m3 and containing solid inclusions in an amount, max, 1.5% by volume with a particle size, max, 1 mm, for which the rate of penetration of corrosion of the material of the flow part parts, max, 0.1 mm/year. The kinematic viscosity of the pumped liquid is up to 30x10-6 m2/s.
Temperature of the pumped liquid from -400 to +1200 C
Pump shaft seal double packing or double mechanical seal.
Material of pump flow parts:
- chrome-Nickel steel 12X18N9TL- " K";
- chrome-Nickel-molybdenum steel 12X18N12MZTL- " E";
- chrome-nickel-molybdenum- copper steel 07KHN25MDTL - " I "-
Nickel-based alloy KHN65MVL and KHN54MSDL - "N".
Electric pump units are available in General industrial, explosion-and fire-safe versions.
Temperature of the pumped liquid from -400 to +1200 C
Pump shaft seal double packing or double mechanical seal.
Material of pump flow parts:
- chrome-Nickel steel 12X18N9TL- " K";
- chrome-Nickel-molybdenum steel 12X18N12MZTL- " E";
- chrome-nickel-molybdenum- copper steel 07KHN25MDTL - " I "-
Nickel-based alloy KHN65MVL and KHN54MSDL - "N".
Electric pump units are available in General industrial, explosion-and fire-safe versions.